RESUMO

OBJECTIVES: The term "mixed pain" has been established when a mixture of different pain components (e.g. nociceptive, neuropathic, and nociplastic) are present. It has gained more and more acceptance amongst pain experts worldwide, but many questions around the concept of mixed pain are still unsolved. The sensation of pain is very personal. Cultural, social, personal experiences, idiomatic, and taxonomic differences should be taken into account during pain assessment. Therefore, a Latin American consensus committee was formed to further elaborate the essentials of mixed pain, focusing on the specific characteristics of the Latin American population. METHODS: The current approach was based on a systematic literature search and review carried out in Medline. Eight topics about the definition, diagnosis, and treatment of mixed pain were discussed and voted for by a Latin American consensus committee and recommendations were expressed. RESULTS: At the end of the meeting a total of 14 voting sheets were collected. The full consensus was obtained for 21 of 25 recommendations (15 strong agreement and 6 unanimous agreement) formulated for the above described 8 topics (7 of the 8 topics had for all questions at least a strong agreement - 1 topic had no agreement for all 4 questions). CONCLUSION: In a subject as complex as mixed pain, a consensus has been reached among Latin American specialists on points related to the definition and essence of this pain, its diagnosis and treatment. Recommendations for diagnosis and treatment of mixed pain in Latin America were raised.


Assuntos
Dor , Humanos , Consenso , América Latina/epidemiologia , Dor/diagnóstico , Dor/etiologia , Dor/fisiopatologia , Medição da Dor , Analgesia/métodos
5.
Int J Implant Dent ; 7(1): 103, 2021 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-34657990

RESUMO

BACKGROUND: New tetragonal zirconia polycrystal dental implants stabilized with yttria (Y-TZP) have appeared in the implantology market in the form of single piece or two-piece zircona implant system. These new type of implants improve the aesthetical properties compared to conventional commercially pure (c.p.) titanium used for implants, although the long term mechanical behavior of these new implants is not yet well known. In orthopaedics, the application of zirconia as femoral balls presented an important controversial use due to the premature fracture once implanted. Y-TZP dental implants can be affected by hydrothermal degradation and its behavior should be analysed to avoid a premature fracture. The scientific question behind the study is to analyse if the degradation mechanism observed in orthopaedics applications of Y-TZP is similar to that of Y-TZP for dental applications. MATERIALS AND METHODS: For this purpose, 30 original Y-TZP dental implants and 42 Y-TZP femoral balls fractured in vivo have been studied. Dental implants were submitted to an accelerated hydrothermal degradation to compare with the femoral balls fractured in vivo. Phase transformation as well as the mechanical behaviour of the degraded samples was studied by X ray diffraction and nanoindentation tests, respectively. RESULTS: Results have shown that the fracture mechanism of dental implants does not resemble the mechanism observed in orthopaedic samples, presenting a good long-term behaviour. CONCLUSION: The results ensure the good performance of zirconia dental implants, because the degradation of the ceramic is very limited and does not affect the mechanical properties.


Assuntos
Implantes Dentários , Teste de Materiais , Propriedades de Superfície , Difração de Raios X , Zircônio
6.
Materials (Basel) ; 13(23)2020 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-33255355

RESUMO

Although ceramic-on-ceramic (CoC) bearings have been shown to produce the smallest amount of wear volume in vitro as well as in vivo studies when used for total hip arthroplasties (THA), concerns about the failure of these bearing surfaces persist due to early failures observed after short postoperative time. In this study, an exhaustive analysis of the early failure occurred on the new generation of ceramic bearings, consisting of a composite alumina matrix-based material reinforced with yttria-stabilized tetragonal zirconia (Y-TZP) particles, chromium dioxide, and strontium crystals, was performed. For this study, 118 CoC bearings from 117 patients were revised. This article describes a group of mechanical failure CoC-bearing BIOLOX THA hip prosthesis patients without trauma history. The retrieved samples were observed under scanning electron microscopy (SEM), composition was analyzed with energy dispersive X-ray spectroscopy (EDX), and damaged surfaces were analyzed by grazing-incidence X-ray diffraction (GI-XRD) and white light interferometry. In the short term, CoC articulations provided similar mechanical behavior and functional outcome to those in XLPE cases. However, 5% more early mechanical failures cases were observed for the ceramic components. Although the fracture rate of third generation CoC couples is low, the present study shows the need to further improve the third generation of CoC-bearing couples for THA. Despite the improved wear compared to other materials, stress concentrators are sources of initial crack propagation, such as those found in the bore-trunnion areas. Moreover, in view of the evidence observed in this study, the chipping observed was due to the presence of monoclinic phase of the Y-TZP instead of tetragonal, which presents better mechanical properties. The results showed that total safety after receiving a THA is still a goal to be pursued.

7.
World Neurosurg ; 122: e156-e167, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30268546

RESUMO

BACKGROUND: Anterior cervical discectomy and fusion with a porous tantalum cage is an accepted method to treat degenerated cervical discs, with good results, similar to those with autologous bone graft and plating at short- and mid-term follow-up. However, to date, long-term follow-up studies have been performed. METHODS: We performed a retrospective, single-center study to evaluate the outcomes of 2 cohorts from a previous prospective randomized controlled trial comparing stand-alone tantalum cage (group 1, 27 patients) with autologous bone graft and plating (group 2, 30 patients) for single-level anterior cervical discectomy and fusion at 11 years of follow-up. The usual clinical and radiological outcomes and "overall success," proposed by the Food and Drug Administration, were evaluated. RESULTS: The improvement in clinical outcomes achieved postoperatively was maintained similarly in the 2 cohorts at 11 years of follow-up. In group 1, the cage had subsided 2-3 mm in 12 patients (44%), segmental lordosis was maintained in 16 patients (59%), adjacent segment degeneration had developed or progressed in 27 of the adjacent segments (50%) in 15 patients (56%), and postoperative nonprogressive deformation of the anterior aspect of the cage was observed in 7 (26%) and minor fragmentation in 3 (11%) patients. In group 2, segmental lordosis was maintained in 90% of the patients and adjacent segment degeneration had developed or progressed in 15 patients (50%). CONCLUSIONS: These results show that the clinical and radiological outcomes achieved at mid-term follow-up using a tantalum cage for single-level anterior cervical discectomy and fusion will be maintained for 11 years postoperatively, similar to the results with autologous bone graft and plating.


Assuntos
Transplante Ósseo , Vértebras Cervicais/cirurgia , Fixação Interna de Fraturas , Degeneração do Disco Intervertebral/cirurgia , Fusão Vertebral/métodos , Adulto , Idoso , Vértebras Cervicais/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Fixadores Internos , Degeneração do Disco Intervertebral/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tantálio , Transplante Autólogo , Resultado do Tratamento , Adulto Jovem
8.
Int J Mol Sci ; 19(9)2018 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-30200178

RESUMO

In this study, highly-interconnected porous titanium implants were produced by powder sintering with different porous diameters and open interconnectivity. The actual foams were produced using high cost technologies: Chemical Vapor Deposition (CVD), Physical Vapor Deposition (PVD), and spark plasma sintering, and the porosity and/or interconnection was not optimized. The aim was to generate a bioactive surface on foams using two different strategies, based on inorganic thermo-chemical treatment and organic coating by peptide adsorption, to enhance osseointegration. Porosity was produced using NaCl as a space holder and polyethyleneglicol as a binder phase. Static and fatigue tests were performed in order to determine mechanical behaviors. Surface bioactivation was performed using a thermo-chemical treatment or by chemical adsorption with peptides. Osteoblast-like cells were cultured and cytotoxicity was measured. Bioactivated scaffolds and a control were implanted in the tibiae of rabbits. Histomorphometric evaluation was performed at 4 weeks after implantation. Interconnected porosity was 53% with an average diameter of 210 µm and an elastic modulus of around 1 GPa with good mechanical properties. The samples presented cell survival values close to 100% of viability. Newly formed bone was observed inside macropores, through interconnected porosity, and on the implant surface. Successful bone colonization of inner structure (40%) suggested good osteoconductive capability of the implant. Bioactivated foams showed better results than non-treated ones, suggesting both bioactivation strategies induce osteointegration capability.


Assuntos
Materiais Revestidos Biocompatíveis/química , Osseointegração/efeitos dos fármacos , Osteoblastos/citologia , Tíbia/cirurgia , Titânio/química , Adsorção , Animais , Sobrevivência Celular , Células Cultivadas , Feminino , Porosidade , Próteses e Implantes , Coelhos , Estresse Mecânico , Propriedades de Superfície , Temperatura
9.
Pain Manag ; 8(1): 45-55, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29182042

RESUMO

Greater trochanteric pain syndrome (GTPS) affects 10-25% of people in developed countries. The underlying etiology for GTPS is most commonly the tendinosis or a tendon tear of the gluteus medius, minimus or both at the greater trochanter; the inflammation of the tendon is not a major feature. We critically evaluated conservative treatment, for which we reviewed 76 publications, grading them according to four levels of evidence. We identified a wide variety of conservative treatment options: home therapy (insoles, walking sticks/crutches, orthotic devices, stretching exercises and preventive measures); physiotherapy (massage and stretching exercises); infiltrations (corticosteroids and local anesthetics); image-guided infiltrations (fluoroscopy and ultrasound); shockwave therapy; platelet-rich plasma injection; and drug therapy. Severe complications associated with infiltrations are extremely rare, as are those associated with shockwave therapy. The most effective treatments were infiltrations with corticosteroids and shockwave therapy. We propose a graded treatment schedule for patients with GTPS.


Assuntos
Tratamento Conservador/métodos , Fêmur/fisiopatologia , Manejo da Dor/métodos , Dor/complicações , Tendinopatia/complicações , Nádegas , Humanos , Avaliação de Resultados em Cuidados de Saúde , Síndrome , Resultado do Tratamento
10.
J Arthroplasty ; 32(12): 3782-3795, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28754580

RESUMO

BACKGROUND: Besides promising results of metal-on-metal (MOM) hip arthroplasty (HA), frequent failures have been reported even in the short term. Many host, surgical, design, metallurgical, and processing factors have been evoked in the base of these events. We have tried to characterize and to evaluate metallurgical and processing features present in this type of implants. METHODS: The acetabular and femoral components of 20 MOM HAs collected from a multicenter retrieval program were examined. All the specimens were inspected with naked eye, with confocal microscopy and vertical scanning interferometry, scanning electron microscopy, back-scattered electron imaging, and energy-dispersive X-ray spectroscopy, in 25 zones of each articular component. RESULTS: Gas pores, shrinkage voids and holes of detached carbides, carbides on surface, embedded particles, scratches and marks of wear, surface discoloration, surface deposits, and tribochemical reaction layers were widely dispersed through a substantial percentage of the total bearing surface in all the implanted components. Surface cup and head voids, and cup scratches showed significant correlation with the clearance of pair. A higher surface damage of the cup and head was observed mainly in the low clearance prostheses. There was no other significant correlation or difference in the incidence and importance of any of these defects between resurfacing hip arthroplasties and total hip arthroplasties, or according to the pair diameter. CONCLUSION: Some metallurgical features and surface damage were significantly present in the retrieved implants of MoM HAs. It would be desirable to improve the structure and metallurgical characteristics of these implants to avoid those effects and optimize their performance.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril , Fêmur/cirurgia , Prótese de Quadril , Próteses Articulares Metal-Metal , Falha de Prótese , Adulto , Idoso , Elétrons , Feminino , Humanos , Interferometria , Masculino , Metais , Microscopia Confocal , Microscopia Eletrônica de Varredura , Pessoa de Meia-Idade , Desenho de Prótese , Propriedades de Superfície
11.
J Mater Sci Mater Med ; 27(10): 151, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27582071

RESUMO

Intervertebral implants should be designed with low load requirements, high friction coefficient and low elastic modulus in order to avoid the stress shielding effect on bone. Furthermore, the presence of a highly interconnected porous structure allows stimulating bone in-growth and enhancing implant-bone fixation. The aim of this study was to obtain bioactive porous titanium implants with highly interconnected pores with a total porosity of approximately 57 %. Porous Titanium implants were produced by powder sintering route using the space holder technique with a binder phase and were then evaluated in an in vivo study. The size of the interconnection diameter between the macropores was about 210 µm in order to guarantee bone in-growth through osteblastic cell penetration. Surface roughness and mechanical properties were analyzed. Stiffness was reduced as a result of the powder sintering technique which allowed the formation of a porous network. Compression and fatigue tests exhibited suitable properties in order to guarantee a proper compromise between mechanical properties and pore interconnectivity. Bioactivity treatment effect in novel sintered porous titanium materials was studied by thermo-chemical treatments and were compared with the same material that had undergone different bioactive treatments. Bioactive thermo-chemical treatment was confirmed by the presence of sodium titanates on the surface of the implants as well as inside the porous network. Raman spectroscopy results suggested that the identified titanate structures would enhance in vivo apatite formation by promoting ion exchange for the apatite formation process. In vivo results demonstrated that the bioactive titanium achieved over 75 % tissue colonization compared to the 40 % value for the untreated titanium.


Assuntos
Osteoblastos/metabolismo , Óxidos/química , Titânio/química , Animais , Materiais Biocompatíveis/química , Força Compressiva , Módulo de Elasticidade , Feminino , Fricção , Teste de Materiais , Microscopia Eletrônica de Varredura , Porosidade , Pós , Próteses e Implantes , Desenho de Prótese , Coelhos , Análise Espectral Raman , Estresse Mecânico , Propriedades de Superfície , Temperatura
12.
Int J Surg Case Rep ; 25: 143-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27372028

RESUMO

INTRODUCTION: Failed hip arthroplasty with intrapelvic acetabular migration can be challenging due to the potential damage of intrapelvic structures. PRESENTATION OF THE CASE: We present a case of a 75 year-old lady with failed hip arthroplasty with loosening of implants and intra-pelvic migration of the cup, antiprotrusio cage mesh, screws and plate. A modified Stoppa approach was performed, a part of the migrated elements were safely removed, the intrapelvic structures were controlled, and the bone defect was reconstructed through the Stoppa approach combined with the lateral window of ilioinguinal approach by means of bone struts and metallic plates, which is a novel technique. Then an extended posterolateral hip approach was done and the acetabulum was reconstructed using porous tantalum augments and morselized allograft. A cemented constrained socket was implanted. After one-year follow-up the patient is able to walk with one crutch without pain. DISCUSSION: Due to intrapelvic migration, the implants used in hip arthroplasty may become entrapped between the anatomical structures lodged in the pelvis and cause damage to them. A careful preoperative assessment and planning are mandatory. A migrated socket can be inaccessible through a conventional hip approach and removal could be very difficult and dangerous. CONCLUSION: The Stoppa approach in hip revision surgery can be a complement to traditional approaches to control the intrapelvic structures, remove migrated implants of previous surgery and reconstruct the pelvic defect.

14.
Hip Int ; 26(2): e11-3, 2016 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-26980240

RESUMO

Constrained liners are a salvage procedure for treating or preventing recurrent dislocations. The Longevity® constrained liner (Zimmer) has a special design with cut-outs on its circumference for avoiding impingement in certain areas and a metallic constraining ring that has to be impacted. The ring impaction may be technical demanding. We recommend preassembly with the head component prior to seating into the acetabular cup, thus avoiding the soft tissue or cement interference and malposition due to bad angle of incidence of impaction force.


Assuntos
Artroplastia de Quadril/métodos , Cimentos Ósseos , Prótese de Quadril , Osteoartrite do Quadril/cirurgia , Humanos , Desenho de Prótese
15.
Open Orthop J ; 7: 227-42, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24082966

RESUMO

The economic burden of periprosthetic infections is enormous, but the number of economic studies dealing with this issue is very scarce. This review tries to know the economic literature existing, assess the value of current data, and recognize the less costly and more effective procedures for prevention, diagnosis and treatment of periprosthetic infections. Forty five studies meeting the inclusion criteria and adhering to the quality criteria used were carefully analyzed to extract the economic data of relevance in evaluating the magnitude of problem and the more cost-effective solutions. However, because the heterogeneity and the low-quality of most of these studies meta-analytical technique has not been possible. Instead, the studies have been reviewed descriptively. Optimizing the antibiotic use in the prevention and treatment of periprosthetic infection, combined with systemic and behavioral changes in the operating room; detecting and treating the high-risk groups; a quick, simple, reliable, safe, and cost-effective diagnosis, and the rationale management of the instituted infection, specifically using the different procedures according to each particular case, could allow to improve outcomes and produce the highest quality of life for patients and the lowest economic impact. Nevertheless, the cost effectiveness of different interventions to prevent and to treat the periprosthetic infection remains unclear.

16.
Clin Orthop Relat Res ; 471(11): 3543-53, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23884802

RESUMO

BACKGROUND: Porous tantalum is an option of cementless fixation for TKA, but there is no randomized comparison with a cemented implant in a mid-term followup. QUESTIONS/PURPOSES: We asked whether a tibial component fixed by a porous tantalum system might achieve (1) better clinical outcome as reflected by the Knee Society Score (KSS) and WOMAC Osteoarthritis Index, (2) fewer complications and reoperations, and (3) improved radiographic results with respect to aseptic loosening compared with a conventional cemented implant. METHODS: We randomized 145 patients into two groups, either a porous tantalum cementless tibial component group (Group 1) or cemented conventional tibial component in posterior cruciate retaining TKA group (Group 2). Patients were evaluated preoperatively and 15 days, 6 months, and 5 years after surgery, using the KSS and the WOMAC index. Complications, reoperations, and radiographic failures were tallied. RESULTS: At 5-year followup the KSS mean was 90.4 (range, 68-100; 95% CI, ± 1.6) for Group 1, and 86.5 (range, 56-99; 95% CI, ± 2.4) for Group 2. The effect size, at 95% CI for the difference between means, was 3.88 ± 2.87. The WOMAC mean was 15.1 (range, 0-51; 95% CI, ± 2.6) for the Group 1, and 19.1 (range, 4-61; 95% CI, ± 2.9) for Group 2. The effect size for WOMAC was -4.0 ± 3.9. There were no differences in the frequency of complications or in aseptic loosening between the two groups. CONCLUSIONS: Our data suggest there are small differences between the uncemented porous tantalum tibial component and the conventional cemented tibial component. It currently is undetermined whether the differences outweigh the cost of the implant and the results of their long-term performance.


Assuntos
Artroplastia do Joelho/instrumentação , Articulação do Joelho/cirurgia , Prótese do Joelho , Tantálio , Idoso , Artroplastia do Joelho/efeitos adversos , Fenômenos Biomecânicos , Cimentos Ósseos/uso terapêutico , Distribuição de Qui-Quadrado , Feminino , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Porosidade , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Falha de Prótese , Radiografia , Recuperação de Função Fisiológica , Reoperação , Fatores de Risco , Espanha , Fatores de Tempo , Resultado do Tratamento
17.
ScientificWorldJournal ; 2013: 821650, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23781163

RESUMO

This review summarizes the existing economic literature, assesses the value of current data, and presents procedures that are the less costly and more effective options for the treatment of periprosthetic infections of knee and hip. Optimizing antibiotic use in the prevention and treatment of periprosthetic infection, combined with systemic and behavioral changes in the operating room, the detection and treatment of high-risk patient groups, as well as the rational management of the existing infection by using the different procedures according to each particular case, could allow for improved outcomes and lead to the highest quality of life for patients and the lowest economic impact. Nevertheless, the cost-effectiveness of different interventions to treat periprosthetic infections remains unclear.


Assuntos
Antibacterianos/economia , Antibacterianos/uso terapêutico , Artroplastia de Quadril/economia , Artroplastia do Joelho/economia , Custos de Cuidados de Saúde/estatística & dados numéricos , Infecções Relacionadas à Prótese/economia , Infecções Relacionadas à Prótese/terapia , Artroplastia de Quadril/estatística & dados numéricos , Artroplastia do Joelho/estatística & dados numéricos , Hospitalização/economia , Hospitalização/estatística & dados numéricos , Humanos , Prevalência , Infecções Relacionadas à Prótese/epidemiologia , Reoperação/economia , Reoperação/estatística & dados numéricos , Fatores de Risco
19.
Spine (Phila Pa 1976) ; 37(20): 1734-41, 2012 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-22466632

RESUMO

STUDY DESIGN: Retrospective cost-effectiveness analysis. OBJECTIVE: To determine the relative cost-effectiveness of anterior cervical discectomy with fusion (ACDF) using a porous tantalum implant compared with autograft with plating, for single-level cervical disc disease with radiculopathy. SUMMARY OF BACKGROUND DATA: ACDF with autograft as an interbody spacer is a generally accepted method to treat degenerated cervical discs with radiculopathy. Concerns about donor site morbidity and the structural characteristics of autograft stimulated investigations of alternative materials. Techniques may differ in their operative risks, complications, outcomes, and resource use. METHODS: A retrospective review of clinical outcomes and total cost of illness for 5 years postsurgery was performed for 61 consecutive patients enrolled for this study. Twenty-eight patients were treated with single-level ACDF using either a stand-alone, porous tantalum implant, without graft inside the implant, and 33 patients received autograft and plating. A cost-effectiveness analysis comparing the 2 ACDF treatment methods was conducted. This article reports clinical assessments, quality adjusted life years gained, and an incremental cost-effectiveness ratio analysis. RESULTS: Patients in both cohorts reported improved clinical outcomes, including neck disability index, visual analogue scale, Short-Form 36, Odom's clinical assessment, and patient satisfaction at 5 years postindex surgery. The mean cost of illness for the study period, including preoperative through 5 years postoperative assessments, was 6806 per patient treated with tantalum and 10,143 per patient receiving autograft and plate. Quality-adjusted life years (QALY) gained were 9.41 and 7.14 for the tantalum and control cohorts, respectively. The cost per QALY for the tantalum group was 723 and 1420 for the control group. The incremental cost-effectiveness ratio of ACDF with a porous tantalum implant compared with ACDF with autograft and plate was -1473 per patient per year for the duration of this study. CONCLUSION: This cost-effectiveness analysis reports favorable results for ACDF procedures utilizing a tantalum implant. The data reported suggest that using porous tantalum as a stand-alone device is less costly and more effective than autograft and plate in ACDF procedures.


Assuntos
Vértebras Cervicais/cirurgia , Degeneração do Disco Intervertebral/cirurgia , Deslocamento do Disco Intervertebral/cirurgia , Próteses e Implantes , Radiculopatia/cirurgia , Fusão Vertebral/métodos , Tantálio , Adulto , Idoso , Análise Custo-Benefício , Discotomia/economia , Discotomia/métodos , Feminino , Humanos , Degeneração do Disco Intervertebral/economia , Deslocamento do Disco Intervertebral/economia , Masculino , Pessoa de Meia-Idade , Porosidade , Anos de Vida Ajustados por Qualidade de Vida , Radiculopatia/economia , Estudos Retrospectivos , Fusão Vertebral/economia , Inquéritos e Questionários , Resultado do Tratamento
20.
J Appl Biomater Funct Mater ; 10(1): 29-36, 2012 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-22467048

RESUMO

AIM: The effective results shown in the porous systems of tantalum employed for the use of osseointegrates has been demonstrated by means of animal experimentation. However, there is a total lack of any research studies on the osseointegration of tantalum implants from retrieval of the same after a period of time whereby the material had been implanted within the human body. MATERIALS AND METHODS: For this study, five rod implants used for the treatment of avascular necrosis of the femoral head were retrieved following collapse of the femoral head and conversion to total hip arthroplasty. The time of implantation ranged between six weeks and twenty months. RESULTS: Observation during this study has confirmed the effectiveness of osseointegration within this period of time. New bone was observed around and within the porous system of the on rod devices at retrieval date. The bone ingrowth, however, proved to be slower and less intense than that resulting within animal species during the first few months after implantation. CONCLUSIONS: Nevertheless, the results obtained in the quantitative assessment of this process proved to be similar to those results achieved by other authors in previous experimental work studies.


Assuntos
Necrose da Cabeça do Fêmur/cirurgia , Prótese de Quadril , Tantálio/análise , Humanos , Osseointegração , Porosidade , Estresse Mecânico , Tantálio/química
SELEÇÃO DE REFERÊNCIAS